产品介绍

住宅建筑外墙博天堂娱乐厅应符合哪些规定?
住宅建筑外墙博天堂娱乐厅应符合哪些规定?
文章来源:本站原创  作者:网站管理员  浏览:21 更新时间:2018-06-13 13:32:51

住宅建筑外墙博天堂娱乐厅应符合哪些规定?
What regulations should be applied to external insulation materials for residential buildings?
1、高度大于等于100m的建筑,其博天堂娱乐厅的燃烧性能应为A级。
1, the building with a height greater than or equal to 100m has a grade of combustion property.
2、高度大于等于60m小于100m的建筑,其博天堂娱乐厅的燃烧性能不应低于B2级。当采用B2级博天堂娱乐厅时,每层应设置水平防火隔离带。
2, the building with a height greater than or equal to 60m is less than 100m, and its combustion properties of insulation materials should not be lower than B2 grade. When using B2 insulation material, a horizontal fire isolation belt should be installed on each floor.
3、高度大于等于24m小于60m的建筑,其博天堂娱乐厅的燃烧性能不应低于B2级。当采用B2级博天堂娱乐厅时,每两层应设置水平防火隔离带。
3, the building with a height greater than or equal to 24m is less than 60m, and its combustion properties of insulation materials should not be lower than B2 grade. When adopting B2 insulation material, a horizontal fire isolation belt should be installed on every two floors.
4、高度小于24m的建筑,其博天堂娱乐厅的燃烧性能不应低于B2级。其中,当采用B2级博天堂娱乐厅时,每三层应设置水平防火隔离带。
4, the building with a height of less than 24m should not be less than B2 in its combustion properties. Among them, when using B2 insulation material, every three levels should be equipped with horizontal fire isolation belt.